Power cable with tinned copper braid shield, fire retardant and halogens free
Cca-s1a,d1,a1
For fixed indoor and outdoor installation in dry or wet environments. They can be installed on metal structures, on platforms, pipes, conduits and similar systems. Also for indirect burial
Suitable for the transport of energy and in particular for the supply of electric motors controlled by an inverter / converter Siemens type. The large section of the shield serves to reduce the transmission of electromagnetic noise generated by the motor control.
| Caratteristiche | Valori | Norme |
|---|---|---|
| Conductors | annealed red copper Cl.5 | CEI EN 60228 |
| Insulation | LSZH special cross-linked compound | CEI EN 50363 |
| Cores colour | CEI UNEL 00722 - HD 308 | |
| Assembling | with grounding conductors in the gaps | |
| Screen: | Al/Pet tape with metal side towards the outside | |
| Screen: | braid of annealed tinned copper | |
| Sheath | LSZH thermoplastic compound | CEI EN 50363 |
| Sheath colour | black RAL 9005 or grey RAL 7001 | |
| Current capacity | DIN VDE 0289-4 | |
| Rated voltage Uo/U | 0,6/1 kV | |
| Max voltage | 1,2 Kv (Frequency converters max 690 V) | |
| Testing voltage | 4 kV | |
| Max working temperature | 90 °C | |
| Short-circuit temperature | 250 °C | |
| Min. installation temperature | 0 °C | |
| Bending radius | Ø x 8 | |
| Printing | BERICA CAVI S.P.A. ITALY EMV 2XSLCH-J 0,6/1 kV Cca-s1a,d1,a1 CE Type -Year/Lot -00000 m |
| Caratteristiche | Valori | Norme |
|---|---|---|
| SYSTEM AVCP | 1+ | EN 50575:2014 + A1:2016 |
| Classification | Cca-s1a,d1,a1 | UNI EN 13501-6 |
| Cca | Heat release and flame spread(FS ≤ 2m) | EN 50399 |
| s1a | Smoke transmittance ≥ 80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2/s) | EN 50399 + EN 61034-2 |
| d1 | No flaming droplets/particles persisting longer than 10 seconds | EN 50399 |
| a1 | Gas acidity (Conductivity 4.3) | EN 50267-2-3 |
| Flame propagation (H ≤ 425 mm) | EN 60332-1-2 |
TIPO N° x mm2 | Ø ESTERNO MEDIO mm | PESO MEDIO kg/km | CODICE |
|---|---|---|---|
| 3x2,5+3G0,50 | 11.4 | 200 | B57C03250LSZH |
| 3x4+3G0,75 | 13.4 | 275 | B57C03400LSZH |
| 3x6+3G1 | 14.3 | 365 | B57C03600LSZH |
| 3x10+3G1,5 | 17.3 | 510 | B57C031000LSZH |
| 3x16+3G2,5 | 19.7 | 715 | B57C031600LSZH |
| 3x25+3G4 | 23 | 1060 | B57C032500LSZH |
| 3x35+3G6 | 24.6 | 1430 | B57C033500LSZH |
| 3x50+3G10 | 29.2 | 2070 | B57C035000LSZH |
| 3x70+3G10 | 33.1 | 2595 | B57C037000LSZH |
The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website
TYPE mm2 | ø ESTERNO MEDIO mm | Average weight kg/km | CODE |
|---|
TIPO N° x mm | Ø ESTERNO MEDIO mm | PESO MEDIO kg/km | CODICE |
|---|---|---|---|
| 3x2,5+3G0,50 | 11.4 | 200 | B57C03250LSZH |
| 3x4+3G0,75 | 13.4 | 275 | B57C03400LSZH |
| 3x6+3G1 | 14.3 | 365 | B57C03600LSZH |
| 3x10+3G1,5 | 17.3 | 510 | B57C031000LSZH |
| 3x16+3G2,5 | 19.7 | 715 | B57C031600LSZH |
| 3x25+3G4 | 23 | 1060 | B57C032500LSZH |
| 3x35+3G6 | 24.6 | 1430 | B57C033500LSZH |
| 3x50+3G10 | 29.2 | 2070 | B57C035000LSZH |
| 3x70+3G10 | 33.1 | 2595 | B57C037000LSZH |
The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website
For fixed indoor and outdoor installation in dry or wet environments. They can be installed on metal structures, on platforms, pipes, conduits and similar systems. Also for indirect burial
Suitable for the transport of energy and in particular for the supply of electric motors controlled by an inverter / converter Siemens type. The large section of the shield serves to reduce the transmission of electromagnetic noise generated by the motor control.
| Caratteristiche | Valori | Norme |
|---|---|---|
| Conductors | annealed red copper Cl.5 | CEI EN 60228 |
| Insulation | LSZH special cross-linked compound | CEI EN 50363 |
| Cores colour | CEI UNEL 00722 - HD 308 | |
| Assembling | with grounding conductors in the gaps | |
| Screen: | Al/Pet tape with metal side towards the outside | |
| Screen: | braid of annealed tinned copper | |
| Sheath | LSZH thermoplastic compound | CEI EN 50363 |
| Sheath colour | black RAL 9005 or grey RAL 7001 | |
| Current capacity | DIN VDE 0289-4 | |
| Rated voltage Uo/U | 0,6/1 kV | |
| Max voltage | 1,2 Kv (Frequency converters max 690 V) | |
| Testing voltage | 4 kV | |
| Max working temperature | 90 °C | |
| Short-circuit temperature | 250 °C | |
| Min. installation temperature | 0 °C | |
| Bending radius | Ø x 8 | |
| Printing | BERICA CAVI S.P.A. ITALY EMV 2XSLCH-J 0,6/1 kV Cca-s1a,d1,a1 CE Type -Year/Lot -00000 m |
| Caratteristiche | Valori | Norme |
|---|---|---|
| SYSTEM AVCP | 1+ | EN 50575:2014 + A1:2016 |
| Classification | Cca-s1a,d1,a1 | UNI EN 13501-6 |
| Cca | Heat release and flame spread(FS ≤ 2m) | EN 50399 |
| s1a | Smoke transmittance ≥ 80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2/s) | EN 50399 + EN 61034-2 |
| d1 | No flaming droplets/particles persisting longer than 10 seconds | EN 50399 |
| a1 | Gas acidity (Conductivity 4.3) | EN 50267-2-3 |
| Flame propagation (H ≤ 425 mm) | EN 60332-1-2 |
TIPO N° x mm2 | Ø ESTERNO MEDIO mm | PESO MEDIO kg/km | CODICE |
|---|---|---|---|
| 3x2,5+3G0,50 | 11.4 | 200 | B57C03250LSZH |
| 3x4+3G0,75 | 13.4 | 275 | B57C03400LSZH |
| 3x6+3G1 | 14.3 | 365 | B57C03600LSZH |
| 3x10+3G1,5 | 17.3 | 510 | B57C031000LSZH |
| 3x16+3G2,5 | 19.7 | 715 | B57C031600LSZH |
| 3x25+3G4 | 23 | 1060 | B57C032500LSZH |
| 3x35+3G6 | 24.6 | 1430 | B57C033500LSZH |
| 3x50+3G10 | 29.2 | 2070 | B57C035000LSZH |
| 3x70+3G10 | 33.1 | 2595 | B57C037000LSZH |
To receive more information about our product range, fill the form on this page.
To receive more information about our product range, fill the form on this page.
Adding {{itemName}} to cart
Added {{itemName}} to cart