Search Products

Armored

FG16OFR16 0,6/1kV

Power, control and signalling cables, steel wire armoured, fire retardant and low halogens emission.

BericaCavi

FG16OFR16_0,6-1kV_10612
Legend
  1. Conductor
  2. Insulation
  3. Inner sheath:
  4. Armour:
  5. Sheath

CPR classifications

Cca-s3,d1,a3

Details
Key features

For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial

Application

Suitable for energy transport and the transmission of signals and controls where a certain level of protection mechanical is required (rodents and termites). In environments that do not face with high risk of fire as buildings intended for civil use, with a fire height less than 24 m, waiting room, bar, restaurant, medical studio. (Low risk - bunch laying )

Structure
FG16OFR16_0,6-1kV_10612-costruzione
Legend
  1. Conductor
  2. Insulation
  3. Inner sheath:
  4. Armour:
  5. Sheath
Technical specifications EN
Caratteristiche Valori Norme
Conductors: annealed red copper Cl.5 CEI EN 60228 (Table 9)
Insulation : LSZH compound G16 quality CEI EN 50363
Cores colour : CEI UNEL 00722 - HD 308
Inner sheath: Thermoplastic compound CEI EN 50363
Armour: Steel wire with steel tape wrapped helically
Sheath: Thermoplastic compound R16 quality CEI EN 50363
Sheath colour : Grey RAL 7035
Low halogens emission: (< 22%) CEI EN 50267-2-1 - IEC 60754-1
DC resistance: according to CEI EN 60228 (Table 9)
Current capacity : CEI UNEL 35024/1 - CEI UNEL 35026
Rated voltage Uo/U: 0,6/1 kV
Max voltage : 1,2 kV
Testing voltage : 4 kV
Max working temperature : 90 °C
Short-circuit temperature : 250 °C
Min. installation temperature : 0 °C
Bending radius : Ø x 14
Max standard twisting (2x cable) : ≥ 10 twist/meter
UE Regulation 305/2011
Caratteristiche Valori Norme
SYSTEM AVCP 1+ EN 50575:2014 + A1:2016
Classification Cca-s3,d1,a3 UNI EN 13501-6
Cca Heat release and flame spread(FS ≤ 2m) EN 50399
s3 Smoke production (not s1 or s2) EN 50399
d1 No flaming droplets/particles persisting longer than 10 seconds EN 50399
a3 Gas acidity (not a1 or a2) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FG16OFR16 0,6/1 kV Cca-s3,d1,a3 CE Type- Year/Lot - 00000 m .
Variants
TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
2x1,5 12 285 B20C02150
3G1,5 12.5 311 B20C03150
4G1,5 13.3 349 B20C04150
5G1,5 14.3 397 B20C05150
7G1,5 15.2 460 B20C07150
10G1,5 18.4 598 B20C10150
12G1,5 19.2 678 B20C12150
16G1,5 21.1 818 B20C16150
19G1,5 22.1 902 B20C19150
24G1,5 24.9 1093 B20C24150
2x2,5 12.8 329 B20C02250
3G2,5 13.4 369 B20C03250
4G2,5 14.4 420 B20C04250
5G2,5 15.4 476 B20C05250
7G2,5 16.7 579 B20C07250
10G2,5 20.2 772 B20C10250
12G2,5 21.1 856 B20C12250
16G2,5 23.4 1049 B20C16250
19G2,5 24.4 1340 B20C19250
24G2,5 27.4 1405 B20C24250
2x4 14.2 407 B20C02400
3G4 14.8 454 B20C03400
4G4 16.1 542 B20C04400
5G4 17.4 616 B20C05400
2x6 15.7 497 B20C02600
3G6 16.4 573 B20C03600
4G6 17.7 664 B20C04600
5G6 19.3 783 B20C05600
2x10 17.8 658 B20C021000
3G10 18.9 772 B20C031000
4G10 20.7 931 B20C041000
5G10 22.4 1087 B20C051000
2x16 20.6 897 B20C021600
3G16 21.7 1052 B20C031600
4G16 23.8 1276 B20C041600
2x25 24.2 1225 B20C022500
3G25 25.6 1466 B20C032500
4G25 28.1 1774 B20C042500
3x35+1G25 32.1 1800 B20C043500
3x50+1G25 35.2 2420 B20C045000

The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website

Variants
TYPE
mm2
ø ESTERNO MEDIO
mm
Average weight
kg/km
CODE
TIPO
N° x mm
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
2x1,5 12 285 B20C02150
3G1,5 12.5 311 B20C03150
4G1,5 13.3 349 B20C04150
5G1,5 14.3 397 B20C05150
7G1,5 15.2 460 B20C07150
10G1,5 18.4 598 B20C10150
12G1,5 19.2 678 B20C12150
16G1,5 21.1 818 B20C16150
19G1,5 22.1 902 B20C19150
24G1,5 24.9 1093 B20C24150
2x2,5 12.8 329 B20C02250
3G2,5 13.4 369 B20C03250
4G2,5 14.4 420 B20C04250
5G2,5 15.4 476 B20C05250
7G2,5 16.7 579 B20C07250
10G2,5 20.2 772 B20C10250
12G2,5 21.1 856 B20C12250
16G2,5 23.4 1049 B20C16250
19G2,5 24.4 1340 B20C19250
24G2,5 27.4 1405 B20C24250
2x4 14.2 407 B20C02400
3G4 14.8 454 B20C03400
4G4 16.1 542 B20C04400
5G4 17.4 616 B20C05400
2x6 15.7 497 B20C02600
3G6 16.4 573 B20C03600
4G6 17.7 664 B20C04600
5G6 19.3 783 B20C05600
2x10 17.8 658 B20C021000
3G10 18.9 772 B20C031000
4G10 20.7 931 B20C041000
5G10 22.4 1087 B20C051000
2x16 20.6 897 B20C021600
3G16 21.7 1052 B20C031600
4G16 23.8 1276 B20C041600
2x25 24.2 1225 B20C022500
3G25 25.6 1466 B20C032500
4G25 28.1 1774 B20C042500
3x35+1G25 32.1 1800 B20C043500
3x50+1G25 35.2 2420 B20C045000

The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website

Related products

FG16ONR16_0,6-1kV_10612

Power, control and signalling cables, steel tape armoured, fire retardant and low halogens emission.

FG16OFR16_0,6-1kV_10612

Power, control and signalling cables, steel wire armoured, fire retardant and low halogens emission.

FG16OAM16_0,6-1kV_10609

Power, control and signalling cables, steel braid armoured, fire retardant and halogen-free.

FG16OAR16_0,6-1kV_10610

Power, control and signalling cables, steel braid armoured, fire retardant and low halogens emission.

FG16OFM16_0,6-1kV_10611

Power, control and signalling cables, steel wire armoured, fire retardant and halogen-free.

Applications

Domotics & BMS

Cables that guarantee a safe data transmission line in home automation systems and, in general, for interconnecting equipment and instruments.

Electrical Appliances & Lighting

Cables for electric signs, for connecting and powering household appliances and mobile tools.

Electronics & Audio

Screened and unscreened cables for transmission and signaling in fixed fire detection systems or according to CPR guidelines.

Energy & Industry

Cables for powering electric motors, signaling and command, armored or screened according to installation requirements.

Green energy

Cables for photovoltaic systems resistant to UV rays.

Industrial automation

Cables for power supply, signaling and control of industrial equipment.

Security

Screened and unscreened cables for transmission of data and signals in case of fire or video surveillance enviroments.

Telecoms

Screened cables for transmission of data in telecommunication environments.

Key features

For fixed indoor and outdoor installation even in wet environments. They can be installed on wall and metal structures, on platforms, pipes, conduits and similar systems. Cable for direct and indirect burial

Application

Suitable for energy transport and the transmission of signals and controls where a certain level of protection mechanical is required (rodents and termites). In environments that do not face with high risk of fire as buildings intended for civil use, with a fire height less than 24 m, waiting room, bar, restaurant, medical studio. (Low risk – bunch laying )

Legend

  1. Conductor
  2. Insulation
  3. Inner sheath:
  4. Armour:
  5. Sheath

Technical specifications EN

Caratteristiche Valori Norme
Conductors: annealed red copper Cl.5 CEI EN 60228 (Table 9)
Insulation : LSZH compound G16 quality CEI EN 50363
Cores colour : CEI UNEL 00722 - HD 308
Inner sheath: Thermoplastic compound CEI EN 50363
Armour: Steel wire with steel tape wrapped helically
Sheath: Thermoplastic compound R16 quality CEI EN 50363
Sheath colour : Grey RAL 7035
Low halogens emission: (< 22%) CEI EN 50267-2-1 - IEC 60754-1
DC resistance: according to CEI EN 60228 (Table 9)
Current capacity : CEI UNEL 35024/1 - CEI UNEL 35026
Rated voltage Uo/U: 0,6/1 kV
Max voltage : 1,2 kV
Testing voltage : 4 kV
Max working temperature : 90 °C
Short-circuit temperature : 250 °C
Min. installation temperature : 0 °C
Bending radius : Ø x 14
Max standard twisting (2x cable) : ≥ 10 twist/meter

UE Regulation 305/2011

Caratteristiche Valori Norme
SYSTEM AVCP 1+ EN 50575:2014 + A1:2016
Classification Cca-s3,d1,a3 UNI EN 13501-6
Cca Heat release and flame spread(FS ≤ 2m) EN 50399
s3 Smoke production (not s1 or s2) EN 50399
d1 No flaming droplets/particles persisting longer than 10 seconds EN 50399
a3 Gas acidity (not a1 or a2) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FG16OFR16 0,6/1 kV Cca-s3,d1,a3 CE Type- Year/Lot - 00000 m .

Variants

TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
2x1,5 12 285 B20C02150
3G1,5 12.5 311 B20C03150
4G1,5 13.3 349 B20C04150
5G1,5 14.3 397 B20C05150
7G1,5 15.2 460 B20C07150
10G1,5 18.4 598 B20C10150
12G1,5 19.2 678 B20C12150
16G1,5 21.1 818 B20C16150
19G1,5 22.1 902 B20C19150
24G1,5 24.9 1093 B20C24150
2x2,5 12.8 329 B20C02250
3G2,5 13.4 369 B20C03250
4G2,5 14.4 420 B20C04250
5G2,5 15.4 476 B20C05250
7G2,5 16.7 579 B20C07250
10G2,5 20.2 772 B20C10250
12G2,5 21.1 856 B20C12250
16G2,5 23.4 1049 B20C16250
19G2,5 24.4 1340 B20C19250
24G2,5 27.4 1405 B20C24250
2x4 14.2 407 B20C02400
3G4 14.8 454 B20C03400
4G4 16.1 542 B20C04400
5G4 17.4 616 B20C05400
2x6 15.7 497 B20C02600
3G6 16.4 573 B20C03600
4G6 17.7 664 B20C04600
5G6 19.3 783 B20C05600
2x10 17.8 658 B20C021000
3G10 18.9 772 B20C031000
4G10 20.7 931 B20C041000
5G10 22.4 1087 B20C051000
2x16 20.6 897 B20C021600
3G16 21.7 1052 B20C031600
4G16 23.8 1276 B20C041600
2x25 24.2 1225 B20C022500
3G25 25.6 1466 B20C032500
4G25 28.1 1774 B20C042500
3x35+1G25 32.1 1800 B20C043500
3x50+1G25 35.2 2420 B20C045000
Ricerca prodotti

Contact Us for more information

To receive more information about our product range, fill the form on this page.

Request more information

Fill the form below to request more information about this product:
FG16OFR16 0,6/1kV

Contact Us for more information

To receive more information about our product range, fill the form on this page.

Request more information

Fill the form below to request more information about this product:
FG16OFR16 0,6/1kV

Reserved area

Coming soon