Power, controls and signalling cables with Al/Pet tape and red copper braid shield, fire retardant low halogens emission and oil resistant.

Cca-s3,d1,a3
For fixed indoor installation in dry or wet environments and temporarily outdoor. They can be installed in cable trays, pipes, conduits and similar systems. Not for direct burial.
They are suitable for energy transport and the transmission of signals and controls, where a certain level of protection against electromagnetic interference ( Copper braid) and electrostatic (aluminum / polyester tape). In environments that do not face with high risk of fire as buildings intended for civil use, with a fire height less than 24 m, waiting room, bar, restaurant, medical studio. (Low risk - bunch laying)

| Caratteristiche | Valori | Norme |
|---|---|---|
| Conductors: | annealed red copper | CEI EN 60228 (Table 9) |
| Insulation : | PVC S18 quality | CEI 20-11/0-1 (CEI EN 50363) |
| Cores colour: | UNEL 00722 or Black numbered | CEI UNEL 00722 |
| Screen: | Al/Pet tape | |
| Screen: | braid of annealed red copper | |
| Sheath: | PVC R18 quality | CEI 20-11/0-1 (CEI EN 50363) |
| Sheath colour : | brown | |
| Low halogens emission: | (< 22%) | CEI EN 50267-2-1 - IEC 60754-1 |
| Oil resistant: | CEI 20-34/0-1 | |
| DC resistance: | CEI EN 60228 (Table 9) | |
| Rated voltage Uo/U: | 450/750V | |
| Max voltage: | 825 V | |
| Testing voltage : | 2500 V | |
| Max working temperature : | 70 °C | |
| Short circuit temperature: | 160 °C | |
| Min. installation temperature: | -15 °C | |
| Bending radius: | Ø x 8 | |
| Max standard twisting (2x cable): | ≥ 10 twist/meter |
| Caratteristiche | Valori | Norme |
|---|---|---|
| SYSTEM AVCP | 1+ | EN 50575:2014 + A1:2016 |
| Classification | Cca-s3,d1,a3 | UNI EN 13501-6 |
| Cca | Heat release and flame spread(FS ≤ 2m) | EN 50399 |
| s3 | Smoke production (not s1 or s2) | EN 50399 |
| d1 | No flaming droplets/particles persisting longer than 10 seconds | EN 50399 |
| a3 | Gas acidity (not a1 or a2) | EN 50267-2-3 |
| Flame propagation (H ≤ 425 mm) | EN 60332-1-2 | |
| Printing: | BERICA CAVI S.P.A. ITALY FS18OHH2R18 300/500V CEI UNEL 35722 Cca-s3,d1,a3 CE Type -Year/Lot - 00000 m . |
The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website
TYPE |
ø ESTERNO MEDIO mm |
Average weight kg/km |
CODE |
|---|
TIPO N° x mm |
Ø ESTERNO MEDIO mm |
PESO MEDIO kg/km |
CODICE |
|---|---|---|---|
| 2x1,5 | 7.4 | 74 | B07C02150 |
| 3G1,5 | 7.7 | 93 | B07C03150 |
| 4G1,5 | 8.3 | 113 | B07C04150 |
| 5G1,5 | 9.2 | 138 | B07C05150 |
| 2x2,5 | 9.1 | 113 | B07C02250 |
| 3G2,5 | 9.5 | 144 | B07C03250 |
| 4G2,5 | 10.3 | 176 | B07C04250 |
| 5G2,5 | 11.4 | 215 | B07C05250 |
The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website
For fixed indoor installation in dry or wet environments and temporarily outdoor. They can be installed in cable trays, pipes, conduits and similar systems. Not for direct burial.
They are suitable for energy transport and the transmission of signals and controls, where a certain level of protection against electromagnetic interference ( Copper braid) and electrostatic (aluminum / polyester tape). In environments that do not face with high risk of fire as buildings intended for civil use, with a fire height less than 24 m, waiting room, bar, restaurant, medical studio. (Low risk – bunch laying)
| Caratteristiche | Valori | Norme |
|---|---|---|
| Conductors: | annealed red copper | CEI EN 60228 (Table 9) |
| Insulation : | PVC S18 quality | CEI 20-11/0-1 (CEI EN 50363) |
| Cores colour: | UNEL 00722 or Black numbered | CEI UNEL 00722 |
| Screen: | Al/Pet tape | |
| Screen: | braid of annealed red copper | |
| Sheath: | PVC R18 quality | CEI 20-11/0-1 (CEI EN 50363) |
| Sheath colour : | brown | |
| Low halogens emission: | (< 22%) | CEI EN 50267-2-1 - IEC 60754-1 |
| Oil resistant: | CEI 20-34/0-1 | |
| DC resistance: | CEI EN 60228 (Table 9) | |
| Rated voltage Uo/U: | 450/750V | |
| Max voltage: | 825 V | |
| Testing voltage : | 2500 V | |
| Max working temperature : | 70 °C | |
| Short circuit temperature: | 160 °C | |
| Min. installation temperature: | -15 °C | |
| Bending radius: | Ø x 8 | |
| Max standard twisting (2x cable): | ≥ 10 twist/meter |
| Caratteristiche | Valori | Norme |
|---|---|---|
| SYSTEM AVCP | 1+ | EN 50575:2014 + A1:2016 |
| Classification | Cca-s3,d1,a3 | UNI EN 13501-6 |
| Cca | Heat release and flame spread(FS ≤ 2m) | EN 50399 |
| s3 | Smoke production (not s1 or s2) | EN 50399 |
| d1 | No flaming droplets/particles persisting longer than 10 seconds | EN 50399 |
| a3 | Gas acidity (not a1 or a2) | EN 50267-2-3 |
| Flame propagation (H ≤ 425 mm) | EN 60332-1-2 | |
| Printing: | BERICA CAVI S.P.A. ITALY FS18OHH2R18 300/500V CEI UNEL 35722 Cca-s3,d1,a3 CE Type -Year/Lot - 00000 m . |
TIPO N° x mm2 |
Ø ESTERNO MEDIO mm |
PESO MEDIO kg/km |
CODICE |
|---|---|---|---|
| 2x1,5 | 7.4 | 74 | B07C02150 |
| 3G1,5 | 7.7 | 93 | B07C03150 |
| 4G1,5 | 8.3 | 113 | B07C04150 |
| 5G1,5 | 9.2 | 138 | B07C05150 |
| 2x2,5 | 9.1 | 113 | B07C02250 |
| 3G2,5 | 9.5 | 144 | B07C03250 |
| 4G2,5 | 10.3 | 176 | B07C04250 |
| 5G2,5 | 11.4 | 215 | B07C05250 |
To receive more information about our product range, fill the form on this page.
Adding {{itemName}} to cart