Fire Resistant

FTS29OM16 100/100V LSZH PH120 CEI 20-105 UNI 9795

Electrical cables for applications in automatic fixed systems for revelation and signalling fire alarms with particular reaction to fire characteristics that comply with the Construction Products Regulation (CPR). Cables with additional fire resistance characteristics. (Voice evacuation)

BericaCavi

FTS29OM16_100-100V_LSZH_PH120_CEI20-105_UNI9795-10644
Legend
  1. Conductor
  2. Flame protection
  3. Insulation
  4. Sheath

CPR classifications

Cca-s1b,d1,a1

Details
Key features

For fixed protected installation in conduits ( embedded or surface mounted ) or similar closed systems. They can be laid in the same conduit with circuits of electrical systems with rated voltage up to 400 V to ground, typically in 230/400 V power systems.

Application

Can be used to connect the equipment of fixed automatic revelation and manual fire alarm, whether or not linked to extinguishing systems or other protection system (both active than passive type), intended to be installed in buildings, independently of the intended use. They are not suitable for other uses such as emergency lighting, power systems, forced evacuation of smoke and heat, electric or emergency controls or other similar applications with operating voltage exceeding 100 V AC for which you have to use the cables to CEI 20-45. Suitable in the most risky environments in the event of a fire, such as health facilities, entertainment venues and entertainment in general, gyms and sports centers. Hotels, guest houses, motels, villages, tourist residences - hotels. Schools of every order, grade and type. Exhibitors and / or retailers. Companies and offices with more than 300 people present; Libraries and archives, museums, galleries, exhibitions and exhibitions. Buildings intended for civil use, with a fire height of more than 24m. (Average Risk)

Structure
FTS29OM16_100-100V_LSZH_PH120_CEI20-105_UNI9795-10644-costruzione
Legend
  1. Conductor
  2. Flame protection
  3. Insulation
  4. Sheath
Technical specifications EN
Caratteristiche Valori Norme
Conductors: annealed red copper cl.5 CEI EN 60228 (Table 9)
Flame protection: mica-glass tape
Insulation: LSZH thermoplastic compound CEI 20-11
Cores colour : red and black
Sheath: LSZH special thermoplastic compound CEI 20-11
Sheath colour: purple RAL 4005
Fire retardant : duration 120 min. at temperature of 830 °C (- 0 ÷ + 40 °C) CEI EN 50200
DC resistance: according to CEI EN 60228 (Table 9)
Rated voltage Uo/U: 100/100 V
Testing voltage: 2000 V
Max working temperature: 90 °C
Short-circuit temperature : 160 °C
Min. installation temperature : 0 °C
Bending radius : Ø x 14
Max standard twisting (2x cable) : ≥ 10 twist/meter
UE Regulation 305/2011
Caratteristiche Valori Norme
SYSTEM AVCP 1+ EN 50575:2014 + A1:2016
Classification Cca-s1b,d1,a1 UNI EN 13501-6
Cca Heat release and flame spread(FS ≤ 2m) EN 50399
s1b Smoke transmittance ≥ 60% < 80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2 /s) EN 50399 + EN 61034-2
d1 No flaming droplets/particles persisting longer than 10 seconds EN 50399
a1 Gas acidity (Conductivity 4.3) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FTS29OM16 100/100 V Uo=400 V Cca-s1b,d1,a1 PH120 CEI 20-105 UNI 9795 CE Type - Year/lot - 00000m
Variants
TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
2x1 8 81 B56C02100EV
2x1,5 8.6 76 B56C02150EV
2x2,5 9.8 103 B56C02250EV
2x4 11 188 B56C02400EV
2x6 12.4 258 B56C02600EV

The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website

Related products

UTP4x2x22_AWG_CAT5E_FR_PH120-10684

Data transmission cables, fire resistant, fire retardant and halogen-free.

S-FTP_4x2x22_AWG_CAT5E_FR_PH120-10671
Data transmission cables, Al/Pet tape and tinned copper braid screened, fire resistant, fire retardant and halogen-free.
FTS29OM16_100-100V_LSZH_PH120_CEI20-105_UNI9795-10644

Electrical cables for applications in automatic fixed systems for revelation and signalling fire alarms with particular reaction to fire characteristics that comply with the Construction Products Regulation (CPR). Cables with additional fire resistance characteristics. (Voice evacuation)

FTG18(O)M16_06-1kV_PH120-F120_CEI20-45_10638

Power, control and signalling cables, fire resistant, fire retardant and halogen-free

FG29OHM16_100-100V_LSZH_PH120_CEI20-105_UNI9795_10616

Electrical cables for applications in automatic fixed systems for revelation and signalling fire alarms with particular reaction to fire characteristics that comply with the Construction Products Regulation (CPR). Cables with additional fire resistance characteristics.

EUROSAFE_FLEX_0,6_1kVPH120-FE180_10604

Cables for fire detection sensors, Al/Pet tape screened, fire resistant, fire retardant, halogen-free.

EUROSAFE_JE-H-St-H_300_500V_PH120-E30_E60_10605

"Control and signalling cables, Al/Pet tape screened, fire resistant, fire retardant, halogen-free."

EUROSAFE_Screened_300-500V_PH120-FE180_10606

Power, control and signalling cables, Al/Pet tape screened, fire resistant, fire retardant, halogen-free.

EUROSAFE_Unscreened_300-500VPH120-FE180_10607
Power, control and signalling cables, fire resistant, fire retardant, halogen-free.

Applications

Domotics & BMS

Cables that guarantee a safe data transmission line in home automation systems and, in general, for interconnecting equipment and instruments.

Electrical Appliances & Lighting

Cables for electric signs, for connecting and powering household appliances and mobile tools.

Electronics & Audio

Screened and unscreened cables for transmission and signaling in fixed fire detection systems or according to CPR guidelines.

Energy & Industry

Cables for powering electric motors, signaling and command, armored or screened according to installation requirements.

Green energy

Cables for photovoltaic systems resistant to UV rays.

Industrial automation

Cables for power supply, signaling and control of industrial equipment.

Security

Screened and unscreened cables for transmission of data and signals in case of fire or video surveillance enviroments.

Telecoms

Screened cables for transmission of data in telecommunication environments.

Key features

For fixed protected installation in conduits ( embedded or surface mounted ) or similar closed systems. They can be laid in the same conduit with circuits of electrical systems with rated voltage up to 400 V to ground, typically in 230/400 V power systems.

Application

Can be used to connect the equipment of fixed automatic revelation and manual fire alarm, whether or not linked to extinguishing systems or other protection system (both active than passive type), intended to be installed in buildings, independently of the intended use. They are not suitable for other uses such as emergency lighting, power systems, forced evacuation of smoke and heat, electric or emergency controls or other similar applications with operating voltage exceeding 100 V AC for which you have to use the cables to CEI 20-45. Suitable in the most risky environments in the event of a fire, such as health facilities, entertainment venues and entertainment in general, gyms and sports centers. Hotels, guest houses, motels, villages, tourist residences – hotels. Schools of every order, grade and type. Exhibitors and / or retailers. Companies and offices with more than 300 people present; Libraries and archives, museums, galleries, exhibitions and exhibitions. Buildings intended for civil use, with a fire height of more than 24m. (Average Risk)

Legend

  1. Conductor
  2. Flame protection
  3. Insulation
  4. Sheath

Technical specifications EN

Caratteristiche Valori Norme
Conductors: annealed red copper cl.5 CEI EN 60228 (Table 9)
Flame protection: mica-glass tape
Insulation: LSZH thermoplastic compound CEI 20-11
Cores colour : red and black
Sheath: LSZH special thermoplastic compound CEI 20-11
Sheath colour: purple RAL 4005
Fire retardant : duration 120 min. at temperature of 830 °C (- 0 ÷ + 40 °C) CEI EN 50200
DC resistance: according to CEI EN 60228 (Table 9)
Rated voltage Uo/U: 100/100 V
Testing voltage: 2000 V
Max working temperature: 90 °C
Short-circuit temperature : 160 °C
Min. installation temperature : 0 °C
Bending radius : Ø x 14
Max standard twisting (2x cable) : ≥ 10 twist/meter

UE Regulation 305/2011

Caratteristiche Valori Norme
SYSTEM AVCP 1+ EN 50575:2014 + A1:2016
Classification Cca-s1b,d1,a1 UNI EN 13501-6
Cca Heat release and flame spread(FS ≤ 2m) EN 50399
s1b Smoke transmittance ≥ 60% < 80% (TSP ≤ 50 m2 and SPR ≤ 0.25 m2 /s) EN 50399 + EN 61034-2
d1 No flaming droplets/particles persisting longer than 10 seconds EN 50399
a1 Gas acidity (Conductivity 4.3) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FTS29OM16 100/100 V Uo=400 V Cca-s1b,d1,a1 PH120 CEI 20-105 UNI 9795 CE Type - Year/lot - 00000m

Variants

TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
2x1 8 81 B56C02100EV
2x1,5 8.6 76 B56C02150EV
2x2,5 9.8 103 B56C02250EV
2x4 11 188 B56C02400EV
2x6 12.4 258 B56C02600EV
Ricerca prodotti

Area Riservata

Coming soon

Contattaci per maggiori informazioni

Scrivici per richiedere ulteriori informazioni sui nostri prodotti o servizi.

Richiesta Informazioni

Compila il form per richiedere informazioni sul prodotto:
FTS29OM16 100/100V LSZH PH120 CEI 20-105 UNI 9795

Reserved area

Coming soon

Contact Us for more information

To receive more information about our product range, fill the form on this page.

Request more information

Fill the form below to request more information about this product:
FTS29OM16 100/100V LSZH PH120 CEI 20-105 UNI 9795