Silicon

SIF - FG4 300/500V

High temperature cables with silicone rubber insulation,flame retardant and halogen-free.

BericaCavi

SIF_FG4_300-500V-10672
Legend
  1. Conductor
  2. Insulation
Details
Key features

For fixed installation within equipment.

Application

Suitable for use in home appliances with high heat development and in industrial environments at high and low temperature.

Structure
SIF_FG4_300-500V-10672-costruzione
Legend
  1. Conductor
  2. Insulation
Technical specifications EN
Caratteristiche Valori Norme
Conductors: annealed red or tinned copper cl.5 CEI EN 60228 (Table 9)
Insulation: Silicone rubber
Insulation colour: On request
Flame retardant: CEI EN 60332-1-2
Halogens free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
DC resistance: According to CEI EN 60228 (Table 9)
Rated voltage Uo/U: 300/500 V
Max voltage: 550 V
Testing voltage: 2000 V
Max working temperature: 180 °C
Short-circuit temperature : 350 °C
Min. installation temperature : -40 °C
Bending radius : Ø x 3
Variants
TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
1x0,50 2.15 8.5 B2501050*
1x0,75 2.35 12 B2501075*
1x1 2.5 14.8 B2501100*
1x1,5 2.8 20.5 B2501150*
1x2,5 3.45 31.5 B2501250*
1x4 4.25 48 B2501400*
1x6 4.8 72 B2501600*
1x10 6.2 120 B25011000*
1x16 7.7 187 B25011600*
1x25 9.4 286 B25012500*
1x35 10.6 390 B25013500*
1x50 12.5 550 B25015000*
1x70 14.3 750 B25017000*
1x95 16.7 1030 B25019500*
1x120 19 1260 B250112000*
*Add colour ex: RED; GV

The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website

Related products

SIHF-GL-P_FG4G4T1A_300-500V-10677
High temeprature cables with silicone rubber insulation and sheath, glass-fibre tape, steel braid armoured, flame retardant and halogen-free.
SIF-GL_FG4T2_300-500V-10674

High temperature cables with silicone rubber insulation, glass-fibre braid, flame retardant and halogen-free.

SIHF_FG4G4_300-500V-10675

High temperature cables with silicone rubber insulation and sheath, flame retardant and halogen-free.

SIHF-GL_FG4G4T2_300-500V-10676
High temperature cables with silicone rubber insulation and sheath, glass-fibre braid, flame retardant and halogen-free.
SIF_FG4_300-500V-10672

High temperature cables with silicone rubber insulation,flame retardant and halogen-free.

FG4G4H2G4_300-500V_10618

High temperature cables with silicone rubber insulation and sheath, red copper braid shielded, flame retardant and halogen-free.

FG4OR_300-500V_10621
High temperature cables up to 105 °C with silicone rubber insulation, PVC sheath, flame retardant, low halogen emission.
Cavi_TIPO_FTV_300-500V_10594

High temperature cables, PTFE insulated with glass-fiber tape and braid, flame retardant.

Applications

Domotics & BMS

Cables that guarantee a safe data transmission line in home automation systems and, in general, for interconnecting equipment and instruments.

Electrical Appliances & Lighting

Cables for electric signs, for connecting and powering household appliances and mobile tools.

Electronics & Audio

Screened and unscreened cables for transmission and signaling in fixed fire detection systems or according to CPR guidelines.

Energy & Industry

Cables for powering electric motors, signaling and command, armored or screened according to installation requirements.

Green energy

Cables for photovoltaic systems resistant to UV rays.

Industrial automation

Cables for power supply, signaling and control of industrial equipment.

Security

Screened and unscreened cables for transmission of data and signals in case of fire or video surveillance enviroments.

Telecoms

Screened cables for transmission of data in telecommunication environments.

Key features

For fixed installation within equipment.

Application

Suitable for use in home appliances with high heat development and in industrial environments at high and low temperature.

Legend

  1. Conductor
  2. Insulation

Technical specifications EN

Caratteristiche Valori Norme
Conductors: annealed red or tinned copper cl.5 CEI EN 60228 (Table 9)
Insulation: Silicone rubber
Insulation colour: On request
Flame retardant: CEI EN 60332-1-2
Halogens free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
DC resistance: According to CEI EN 60228 (Table 9)
Rated voltage Uo/U: 300/500 V
Max voltage: 550 V
Testing voltage: 2000 V
Max working temperature: 180 °C
Short-circuit temperature : 350 °C
Min. installation temperature : -40 °C
Bending radius : Ø x 3

Variants

TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
1x0,50 2.15 8.5 B2501050*
1x0,75 2.35 12 B2501075*
1x1 2.5 14.8 B2501100*
1x1,5 2.8 20.5 B2501150*
1x2,5 3.45 31.5 B2501250*
1x4 4.25 48 B2501400*
1x6 4.8 72 B2501600*
1x10 6.2 120 B25011000*
1x16 7.7 187 B25011600*
1x25 9.4 286 B25012500*
1x35 10.6 390 B25013500*
1x50 12.5 550 B25015000*
1x70 14.3 750 B25017000*
1x95 16.7 1030 B25019500*
1x120 19 1260 B250112000*
Ricerca prodotti

Area Riservata

Coming soon 2023

Contattaci per maggiori informazioni

Scrivici per richiedere ulteriori informazioni sui nostri prodotti o servizi.

Richiesta Informazioni

Compila il form per richiedere informazioni sul prodotto:
SIF – FG4 300/500V

Reserved area

Coming soon

Arriving April 2023
Days
Hours
Minutes
Seconds

Contact Us for more information

To receive more information about our product range, fill the form on this page.

Request more information

Fill the form below to request more information about this product:
SIF – FG4 300/500V