Search Products

Photovoltaic systems

SOLAR CABLE Armoured 0,6/1kV

Cables for applications in photovoltaic systems, with elastomeric insulation and sheath, steel braid armoured, flame retardant, halogen-free and UV resistant.

BericaCavi

SOLAR-CABLE_Armato_0,6-1kV-10681
Legend
  1. Conductor
  2. Insulation
  3. Assembling:
  4. Armour:
  5. Sheath
Details
Key features

For fixed indoor and outdoor installation, without protection, or inside pipe surface mounted or embedded, or similar closed systems. Possibility of indirect or direct burial.

Application

Suitable for the interconnection of the components of PV systems are characterized by: optimum mechanical properties in a range of operating temperature - 40 to + 90 ° C, high abrasion resistance, tear, UV, ozone , water, flame propagation, low smoke, halogen-free, weather resistance that allows a period equal to the life of the PV system. Moreover, they provide adequate protection against rodents and termites.

Structure
SOLAR-CABLE_Armato_0,6-1kV-10681-costruzione
Legend
  1. Conductor
  2. Insulation
  3. Assembling:
  4. Armour:
  5. Sheath
Technical specifications EN
Caratteristiche Valori Norme
Conductors: annealed tinned copper cl.5 CEI EN 60228 (Table 9)
Insulation: crosslinked non-toxic elastomer
Assembling: Pet tape
Armour: Braid of galvanized steel
Sheath: crosslinked non-toxic elastomer
Sheath colour: black RAL 9005
Flame retardant: CEI EN 60332-1-2
Halogens free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Low toxic gases emission: (toxicity index < 2%) CEI 20-37/4-0
Low smoke emission: (trasmittance > 60%) CEI EN 61034-2
UV resistant: HD 605
Ozone resistant: CEI EN 50396
Long-term behavior: (20000 h a 120°C) CEI EN 60216
Expected life: 25 years
DC resistance: according to CEI EN 60228 (Table 9)
Current capacity : CEI 20-21 - IEC 60287 (Table)
Rated voltage Uo/U: 0,6/1 kVac
Max voltage: 1,2 kVac
Testing voltage: 6,5 kVac
Max working temperature: 90 °C
Short-circuit temperature : 250 °C
Min. installation temperature : -25 °C
Bending radius : Ø x 14
Printing: BERICA CAVI S.P.A. ITALY SOLAR CABLE ARMOUR 1500 Vcc PV1-F IEC 60332-1-2 CE Type - Year/Lot - 00000 m
Variants
TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
1x4 NERO 8.4 116 B8901400N
1x4 ROSSO 8.4 116 B8901400R
1x6 NERO 8.9 144 B8901600N
1x6 ROSSO 8.9 144 B8901600R
1x10 NERO 10.5 207 B89011000N
1x10 ROSSO 10.5 207 B89011000R
1x16 NERO 11.9 283 B89011600N
1x16 ROSSO 11.9 283 B89011600R
1x25 NERO 13.2 381 B89012500N
1x25 ROSSO 13.2 381 B89012500R
1x35 NERO 14.6 490 B89013500N
1x35 ROSSO 14.6 490 B89013500R
1x50 NERO 16.6 672 B89015000N
1x50 ROSSO 16.6 672 B89015000R
1x70 NERO 18.7 854 B89017000N
1x70 ROSSO 18.7 854 B89017000R
1x95 NERO 21.3 1112 B89019500N
1x95 ROSSO 21.3 1112 B89019500R
1x120 NERO 23.9 1395 B890112000N
1x120 ROSSO 23.9 1395 B890112000R
1x150 NERO 25.7 1688 B890115000N
1x150 ROSSO 25.7 1688 B890115000R
1x185 NERO 28.4 2002 B890118500N
1x185 ROSSO 28.4 2002 B890118500R
1x240 NERO 29.6 2626 B890124000N
1x240 ROSSO 29.6 2626 B890124000R

The company reserves the right to modify/adjust, without prior notice, the technical and dimensional information of the products featured on the website

Related products

SOLAR-CABLE_H1Z2Z2-K_CEI-EN50618_IMQ-10682

Cables for applications in photovoltaic systems, with elastomeric insulation and sheath, flame ratardant, halogen-free and UV resistant.

SOLAR-CABLE_2x_0,6-1kV-10680

Cables for applications in photovoltaic systems, with elastomeric insulation and sheath, flame ratardant, halogen-free and UV resistant.

SOLAR-CABLE_Alluminio_0,6-1kV-10679

Cables for applications in photovoltaic systems, with elastomeric insulation and sheath, flame retardant, halogen-free and UV resistant.

SOLAR-CABLE_Armato_0,6-1kV-10681

Cables for applications in photovoltaic systems, with elastomeric insulation and sheath, steel braid armoured, flame retardant, halogen-free and UV resistant.

Applications

Domotics & BMS

Cables that guarantee a safe data transmission line in home automation systems and, in general, for interconnecting equipment and instruments.

Electrical Appliances & Lighting

Cables for electric signs, for connecting and powering household appliances and mobile tools.

Electronics & Audio

Screened and unscreened cables for transmission and signaling in fixed fire detection systems or according to CPR guidelines.

Energy & Industry

Cables for powering electric motors, signaling and command, armored or screened according to installation requirements.

Green energy

Cables for photovoltaic systems resistant to UV rays.

Industrial automation

Cables for power supply, signaling and control of industrial equipment.

Security

Screened and unscreened cables for transmission of data and signals in case of fire or video surveillance enviroments.

Telecoms

Screened cables for transmission of data in telecommunication environments.

Key features

For fixed indoor and outdoor installation, without protection, or inside pipe surface mounted or embedded, or similar closed systems. Possibility of indirect or direct burial.

Application

Suitable for the interconnection of the components of PV systems are characterized by: optimum mechanical properties in a range of operating temperature – 40 to + 90 ° C, high abrasion resistance, tear, UV, ozone , water, flame propagation, low smoke, halogen-free, weather resistance that allows a period equal to the life of the PV system. Moreover, they provide adequate protection against rodents and termites.

Legend

  1. Conductor
  2. Insulation
  3. Assembling:
  4. Armour:
  5. Sheath

Technical specifications EN

Caratteristiche Valori Norme
Conductors: annealed tinned copper cl.5 CEI EN 60228 (Table 9)
Insulation: crosslinked non-toxic elastomer
Assembling: Pet tape
Armour: Braid of galvanized steel
Sheath: crosslinked non-toxic elastomer
Sheath colour: black RAL 9005
Flame retardant: CEI EN 60332-1-2
Halogens free: (< 0,5 mg/g - 0,5%) CEI EN 50267-2-1/2 - IEC 60754-1/2
Low toxic gases emission: (toxicity index < 2%) CEI 20-37/4-0
Low smoke emission: (trasmittance > 60%) CEI EN 61034-2
UV resistant: HD 605
Ozone resistant: CEI EN 50396
Long-term behavior: (20000 h a 120°C) CEI EN 60216
Expected life: 25 years
DC resistance: according to CEI EN 60228 (Table 9)
Current capacity : CEI 20-21 - IEC 60287 (Table)
Rated voltage Uo/U: 0,6/1 kVac
Max voltage: 1,2 kVac
Testing voltage: 6,5 kVac
Max working temperature: 90 °C
Short-circuit temperature : 250 °C
Min. installation temperature : -25 °C
Bending radius : Ø x 14
Printing: BERICA CAVI S.P.A. ITALY SOLAR CABLE ARMOUR 1500 Vcc PV1-F IEC 60332-1-2 CE Type - Year/Lot - 00000 m

Variants

TIPO
N° x mm2
Ø ESTERNO MEDIO
mm
PESO MEDIO
kg/km
CODICE
1x4 NERO 8.4 116 B8901400N
1x4 ROSSO 8.4 116 B8901400R
1x6 NERO 8.9 144 B8901600N
1x6 ROSSO 8.9 144 B8901600R
1x10 NERO 10.5 207 B89011000N
1x10 ROSSO 10.5 207 B89011000R
1x16 NERO 11.9 283 B89011600N
1x16 ROSSO 11.9 283 B89011600R
1x25 NERO 13.2 381 B89012500N
1x25 ROSSO 13.2 381 B89012500R
1x35 NERO 14.6 490 B89013500N
1x35 ROSSO 14.6 490 B89013500R
1x50 NERO 16.6 672 B89015000N
1x50 ROSSO 16.6 672 B89015000R
1x70 NERO 18.7 854 B89017000N
1x70 ROSSO 18.7 854 B89017000R
1x95 NERO 21.3 1112 B89019500N
1x95 ROSSO 21.3 1112 B89019500R
1x120 NERO 23.9 1395 B890112000N
1x120 ROSSO 23.9 1395 B890112000R
1x150 NERO 25.7 1688 B890115000N
1x150 ROSSO 25.7 1688 B890115000R
1x185 NERO 28.4 2002 B890118500N
1x185 ROSSO 28.4 2002 B890118500R
1x240 NERO 29.6 2626 B890124000N
1x240 ROSSO 29.6 2626 B890124000R
Ricerca prodotti

Area Riservata

Coming soon 2023

Contattaci per maggiori informazioni

Scrivici per richiedere ulteriori informazioni sui nostri prodotti o servizi.

Richiesta Informazioni

Compila il form per richiedere informazioni sul prodotto:
SOLAR CABLE Armoured 0,6/1kV

Reserved area

Coming soon

Arriving April 2023
Days
Hours
Minutes
Seconds

Contact Us for more information

To receive more information about our product range, fill the form on this page.

Request more information

Fill the form below to request more information about this product:
SOLAR CABLE Armoured 0,6/1kV