CEI UNEL 35011 | |||||||||
Symbols on the nature and degree of flexibility of the conductors | |||||||||
- | no symbol: copper conductor | ||||||||
A | aluminum conductor | ||||||||
EF | extra flexible wire, stranded or special construction | ||||||||
F | stranded round conductor | ||||||||
FF | highly flexible wire round rope | ||||||||
R | stranded round conductor normal or compact | ||||||||
S | sector-stranded | ||||||||
SU | sector-single conductor wire | ||||||||
U | single conductor wire round | ||||||||
Symbols for insulation | |||||||||
C | paper impregnated with a mixture of normal | ||||||||
C1 | paper impregnated with a mixture of non-migrant | ||||||||
C2 | paper impregnated with a special blend of gas and | ||||||||
C3 | paper impregnated with oil-filled | ||||||||
C4 | paper impregnated with a mixture stabilized | ||||||||
E | blends based on polyethylene thermoplastic | ||||||||
E4 | compound based on cross-linked polyethylene having a characteristic temperature of 85 °C suitable for protective coatings | ||||||||
G | mixture based on natural rubber and / or synthetic with characteristic temperature of 60 ° C, quality EI1 | ||||||||
G4 | silicone rubber compound with characteristic temperature of 180 °C, quality EI2 | ||||||||
G7 | mixture based on ethylene-propylene rubber having a high modulus characteristic temperature of 90 °C | ||||||||
G8 | mixture based on ethylene-propylene rubber is also suitable for cables without having rivestimentoprotettivo characteristic temperature of 85 °C | ||||||||
G9 | elastomeric reticulated low smoke and toxic and corrosive gases suitable for cables without protective coating having the characteristic temperature of 90 °C | ||||||||
G10 | crosslinked rubber compound with low smoke and toxic and corrosive gases with ambient temperatures of 90 °C | ||||||||
G19 | crosslinked rubber compound with low smoke and toxic and corrosive gases with ambient temperatures of 90 °C | ||||||||
G20 | crosslinked insulating compound for low smoke and toxic and corrosive gases with ambient temperatures of 90 °C | ||||||||
M | mineral insulation | ||||||||
M9 | thermoplastic compound with low emission of smoke and corrosive gastossici and with characteristic temperature of 70 °C | ||||||||
R | polyvinyl chloride compound with characteristic temperature of 70 °C, quality TI1 and TI2 | ||||||||
R2 | polyvinyl chloride compound with characteristic temperature of 70 °C, as R2 | ||||||||
R4 | compound based on polyamide resin | ||||||||
R5 | mixture based on fluorocarbon resins | ||||||||
R5F | mixture based on fluorocarbon copolymer resins - tetrafluoroethylene - hexafluoropropylene (FEP) | ||||||||
R5 | mixture based on fluorocarbon resins - perfluorometilviniletere-tetrafluoroethylene copolymer (MFA) | ||||||||
R5P | mixture based on fluorocarbon resins - perfluorpropilviniletere-tetrafluoroethylene copolymer (PFA) | ||||||||
R7 | polyvinyl chloride compound with characteristic temperature of 90 ° C as TI3 | ||||||||
T4 | Sterling canvas (oil-based paints and resins) | ||||||||
V | glass cloth may be impregnated | ||||||||
T | one or more strips of glass or mica glass braid closed | ||||||||
Markings indicating the concentric conductors and screens on single core cables or the individual core of multicore cables | |||||||||
AC | concentric aluminum conductor, if is not a metal sheath | ||||||||
C | concentric copper conductor, if is not a metal sheath | ||||||||
H | screen metallic paper or paper-carbon or aluminum strip | ||||||||
H1 | screen or flat ribbons or wires of copper | ||||||||
H2 | braid or braided copper screen | ||||||||
H3 | screen double braid or double braid copper | ||||||||
H4 | screen of corrugated steel tape longitudinal | ||||||||
H5 | screen coated aluminum tape longitudinally | ||||||||
Q | copper sheath | ||||||||
Symbols related to protective coatings on single core cables or the individual core of multicore cables | |||||||||
Non-metallic coatings: | |||||||||
E | EZ-quality plastic sheath | ||||||||
E4 | sheath of polyethylene quality E4M | ||||||||
G | sheath of natural rubber and / or synthetic quality Gy | ||||||||
G6 | sheath made of polyethylene or chlorinated clorusulforato, quality G6M | ||||||||
K | sheath-based polychloroprene or equivalent products, quality Ky, Kn, Kz | ||||||||
R | sheathed in polyvinyl chloride, as TM1, TM2, RZ | ||||||||
R4 | sheath made of polyamide resin | ||||||||
M1 | plastic sheath with low smoke and toxic gases and corrosive | ||||||||
M2 | elastomeric sheath low smoke and toxic gases and corrosive quality M2 | ||||||||
M3 | elastomeric sheath, with low toxic and corrosive gases, quality M3 | ||||||||
M4 | elastomeric sheath, with low toxic and corrosive gases, quality M4 | ||||||||
T | textile braid (possibly saturated) normal type | ||||||||
T1 | bandage tape glass | ||||||||
T2 | textile braid of special type (eg glass braid) may be impregnated | ||||||||
Metallic coatings: | |||||||||
A | smooth aluminum sheath, or armor braid (shield) wire | ||||||||
A1 | corrugated aluminum sheath | ||||||||
EL | sheath of lead alloy, with an underlying continuity conductor | ||||||||
EP | sheath of lead alloy with no underlying continuity conductor | ||||||||
F | cylindrical wire armouring, usually steel | ||||||||
FJ | wire armouring as above, with outer jute impregnated, or equivalent | ||||||||
H4 | screen of corrugated steel tape longitudinal | ||||||||
H5 | screen coated aluminum tape longitudinally | ||||||||
L | lead alloy sheath | ||||||||
N | normally steel tape armouring | ||||||||
NJ | weave strips as above, with outer jute impregnated or equivalent | ||||||||
P | not lead alloy sheath | ||||||||
Q | copper sheath | ||||||||
Z | weave strips of steel normally | ||||||||
ZJ | weave strips as above, with outer jute impregnated or equivalent | ||||||||
Symbols on the composition and shape of the cables: | |||||||||
- | no symbol: single core cables | ||||||||
O | cores, possibly with its own cover, together with or without fillers to form a virtually round cable | ||||||||
D | cores as above, side by side parallel cable (external form flattened) | ||||||||
X | cores as above, combined with propeller visible (eg cable precordium) | ||||||||
W | cores united parallel with a groove intermediate (divisible flat cable, sharp-edged or rounded) | ||||||||
W1 | parallel souls united with intermediate insulating bars | ||||||||
Any particular organs: | |||||||||
S | bearing organ, usually metal, built-in non-metallic sheath | ||||||||
Y | bearing organ, textile or metal, including between cores or externally attached a wire embedded in the non-metallic sheath. |
CEI HD 361-S4 | |||||||||
Reference to standards: | |||||||||
H | Cable conforming to harmonized standards | ||||||||
- | Non-harmonized cable | ||||||||
National Committees may use any symbol or system that does not conflict with HD 361. If the system laid down by HD 361 is used for non-harmonized cables, it is recommended not to use a prefix symbol. | |||||||||
Rated voltage Uo/U: | |||||||||
01 | 100/100 V | ||||||||
03 | 300/300V | ||||||||
05 | 300/500V | ||||||||
07 | 450/750V | ||||||||
1 | 1000/1000 V* At present, the rated voltage is limited to PV-cables acc. to EN 50618. | ||||||||
Insulating and sheathing materials for non-metallic: | |||||||||
B | Ethylene- propylene rubber for conductor temperature 90 °C | ||||||||
G | Ethylene-vinileacetato | ||||||||
J | Braided glass fiber | ||||||||
M | Mineral | ||||||||
N | Polychloroprene-rubber (or equivalent material) | ||||||||
N2 | Special-rubber compound of polychloroprene for sheathing of welding cable | ||||||||
N4 | Chlorosulphonated polyethylene | ||||||||
N8 | Special-rubber compound of polychloroprene, water resistant | ||||||||
Q | Polyurethane | ||||||||
Q4 | Polyamide | ||||||||
R | Etilepropilene ordinary rubber or equivalent synthetic elastomer to a continuous operation temperature of 60 °C | ||||||||
S | Silicone rubber | ||||||||
T | Textile braid impregnated or not on all the souls | ||||||||
T6 | Textile braid impregnated or not the individual cores of a multicore cable | ||||||||
V | Commonly used polyvinyl chloride (PVC) | ||||||||
V2 | PVC compound for conductor temperature of 90°C | ||||||||
V3 | PVC compound for cable installation at low temperatures | ||||||||
V4 | Ordinary PVC, crosslinked | ||||||||
V5 | Ordinary PVC, special oil resistant | ||||||||
Z | Crosslinked polyolefin-compound for cable with low smoke and non-corrosive gases in the case of fire | ||||||||
Z1 | Thermoplastic polyolefin-compound for cable with low smoke and non-corrosive gas in the case of fire | ||||||||
Z1 | Thermoplastic polyolefin-compound for cable with low smoke and non-corrosive gas in the case of fire | ||||||||
Z2 | Crosslinked polyolefin-compound for cable with low smoke and non-corrosive gases in the case of fire for photovoltaic cable | ||||||||
Z5 | Thermoplastic compound EVM-1 for cable with non-corrosive gases in the case of fir for EV charging cable | ||||||||
Z6 | Crosslinked compound EVM-2 for cable with non-corrosive gases in the case of fire EV charging cable | ||||||||
Metallic coatings: | |||||||||
C | Concentric copper conductor | ||||||||
C4 | Screen of copper in the form of a braid on all the souls | ||||||||
Special building components of a cable: | |||||||||
D3 | Strain-bearing element consisting of one or more components (textile or metallic) placed at the centre of a round cable or distributed inside a flat cable | ||||||||
D5 | Central heart (non-strain-bearing) | ||||||||
Special construction of cable: | |||||||||
No symbol | Round cable | ||||||||
H | H Flat construction of „divisible“ cables and cores, either sheathed or non-sheathed | ||||||||
H2 | Flat construction of „non-divisible“ cables and cords | ||||||||
H6 | Flat cable having 3 or more cores, according to EN 50214 | ||||||||
H7 | Cable with dual layer insulation applied by extrusion | ||||||||
H8 | Cordon extensible | ||||||||
Conductor material: | |||||||||
No symbol | Copper | ||||||||
-A | Aluminium | ||||||||
Shape of conductor: | |||||||||
-D | Flexible conductor of welding cables (flexibility departing from EN 60228 class 5) | ||||||||
-E | Highly flexible conductor of welding cables (flexibility departing from EN 60228 class6) | ||||||||
-F | Flexible conductor of a flexible cable or cord (flexibility according to EN 60228 class | ||||||||
-H | Highly flexible conductor of a flexible cable or cord (flexibility according to EN 60228 | ||||||||
-K | flexible conductor of a cable for fixed installations (unless otherwise specified, flexibility according to EN 60228 class 5) | ||||||||
-R | Rigid, round conductor, stranded | ||||||||
-U | Rigid, round conductor, solid | ||||||||
-Y | Conductor like copper |
CEI UNEL 36011 | |||||||||
Symbols relating to cable communications and telecommunications: | |||||||||
T | Symmetrical cable or cord or wire | ||||||||
TC | Coaxial cable pairs | ||||||||
TO | Optical cable | ||||||||
Symbols of the type of dielectric: | |||||||||
A | Dielectric of paper and dry air | ||||||||
E | Dielectric polyolefin (polypropylene or polyester) compact circular | ||||||||
E1 | Dielectric polyolefin compact + dry air or dry air + shaped polyolefin or polyolefin spacers + dry air | ||||||||
E2 | Polyolefin dielectric cell (or expanded) | ||||||||
E3 | Polyolefin dielectric double-layer (cell + compact) | ||||||||
R | Dielectric polyvinyl chloride | ||||||||
R9 | Dielectric thermoplastic polyester | ||||||||
R4 | Dielectric polyamide | ||||||||
M | Dielectric plastic with low emission of opaque smoke and toxic gases and corrosive | ||||||||
Symbols for the training of each basic element and the stranding of the whole | |||||||||
Q | Training in the fourth element | ||||||||
D | Training element bicoppie DM | ||||||||
G | Stranding of the whole group | ||||||||
Symbols for screens and guards | |||||||||
Screens | |||||||||
H0 | Metal wire in legaspeciale | ||||||||
H | Aluminum tape or plastic, metallic | ||||||||
H1 | Tape or copper wire | ||||||||
H2 | Copper braid | ||||||||
H3 | Double braided copper | ||||||||
Protections | |||||||||
T | Buffering or plugging mixture of continuous | ||||||||
H4 | Steel strip longitudinal edge overlap corrugated | ||||||||
H5 | Clad aluminum tape longitudinal welded to the sheath overlying bordisovrapposti | ||||||||
H6 | Steel tape longitudinal welded and corrugated | ||||||||
H7 | Copper tape longitudinally corrugated hard edges | ||||||||
H8 | Copper tape longitudinal welded | ||||||||
H9 | Plated steel strip longitudinal edges overlapped and sealed to the corrugated sheath above | ||||||||
H10 | Plated copper tape overlapped longitudinal edges welded to the sheath above | ||||||||
H11 | Clad aluminum tape longitudinal edges overlapped and corrugated welded sheath gives the above | ||||||||
H12 | Plated copper tape longitudinal edges overlapped and corrugated welded sheath gives the above | ||||||||
N | Rolled steel strips | ||||||||
N1 | Tape wrapped dielectric | ||||||||
F | Steel Wire | ||||||||
F1 | Dielectric rods | ||||||||
F2 | Braided Steel | ||||||||
Z | Steel Strips | ||||||||
Z1 | Dielectric strips | ||||||||
J | Wrapping with jute preimpiegnata substances anti-rotting | ||||||||
J1 | Binding of synthetic yarn | ||||||||
K | Aramid yarns | ||||||||
K1 | Aramid yarn towel | ||||||||
V | Glass yarns | ||||||||
V1 | Glass yarns buffered | ||||||||
W | Aramid and glass yarn | ||||||||
W1 | Fialti aramid and glass towel | ||||||||
L | Lead alloy pipe | ||||||||
A | Extruded aluminum tube with a smooth surface | ||||||||
A1 | Extruded aluminum tube corrugated surface | ||||||||
A5 | Welded aluminum tube with a smooth surface | ||||||||
A6 | Aluminum tube welded corrugated surface | ||||||||
E | Polyethylene sheath | ||||||||
P | Polyurethane sheath | ||||||||
M | Plastic sheath with low emission of opaque smoke and toxic gases and corrosive | ||||||||
R | Sheath of polyvinyl chloride | ||||||||
R4 | Sheath of polyamide | ||||||||
Symbols of special features: | |||||||||
X | Symbol indicative of the entire cable or special features of its own merit | ||||||||
Y | Conductor similfilo | ||||||||
B | Bipolar cable round | ||||||||
F | Flat cable | ||||||||
D | Ribbon cable divisible | ||||||||
Z | Zip cables (two units each) | ||||||||
S | Self-supporting cable round | ||||||||
S8 | Self-supporting cable with built-in cable |
OTHER EUROPEAN TYPES | |||||||||
Flexibility of the conductors: | |||||||||
Li | Flexible conductor. | ||||||||
f | Very flexible conductor. | ||||||||
re | Solid conductor copper wire only. | ||||||||
rm | Semi-conductor. | ||||||||
rf | Flexible conductor. | ||||||||
Armour: | |||||||||
Q | Steel wire braid armor. | ||||||||
S | Steel wire braid armor. | ||||||||
swa | Steel wire armouring. | ||||||||
swb | Steel wire braid armor. | ||||||||
sta | Steel tape armouring. | ||||||||
R | Steel wire armouring. | ||||||||
B | Steel tape armouring. | ||||||||
Z | Cassette armor. | ||||||||
Shield: | |||||||||
C | Tinned copper braid shield. | ||||||||
D | Spiral shield or tinned copper. | ||||||||
ST | Aluminum tape shield. | ||||||||
CE | Copper braid on each individual soul. | ||||||||
Pimf | A strip of aluminum on the single pair. | ||||||||
PiC | Pair cable with copper braid. | ||||||||
Materials for insulation and sheath: | |||||||||
Y | Common quality PVC. | ||||||||
Yv | PVC thicker. | ||||||||
Yu | PVC flame retardant | ||||||||
Yw | PVC for t = 105 ° C. | ||||||||
X | PVC fence. | ||||||||
2Y | Polyethylene. | ||||||||
02Y | Polyethylene foam. | ||||||||
2X | Crosslinked polyethylene. | ||||||||
4Y | Polyamide | ||||||||
5Y | Polytetrafluoroethylene. | ||||||||
9Y | Polypropylene. | ||||||||
11Y | Polyurethane. | ||||||||
12Y | Polyester elastomer. | ||||||||
G | Rubber | ||||||||
2G | Silicon rubber. | ||||||||
3G | Gom. etilenpropilenica. | ||||||||
4G | Gom. etilenvinilacetato. | ||||||||
5G | Neoprene rubber. | ||||||||
6G | Chlorosulfonated rubber. | ||||||||
H | Halogen free | ||||||||
Installation type: | |||||||||
A | Outdoor cable. | ||||||||
AB | Outdoor cable with lightning protection. | ||||||||
F | Filler buffering water resistant | ||||||||
L | Smooth aluminum sheath | ||||||||
J | Fixed laying cable. | ||||||||
JE | Fixed laying cable (electronics) | ||||||||
-J | Cable with cond. Y/G. | ||||||||
-JZ | Y/G + cond. numbered. | ||||||||
-O | Cable without cond. Y/G. | ||||||||
-OZ | Cable without Y/G and c.numbered. |